318 Keysight M8070A Programming Guide
5 SCPI Command Reference
:PLUGin:OTIMing:STOP
Syntax :PLUGin:OTIMing:STOP ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name to stop.
Description This command stops an output timing measurement addressed by the
measurement name identifier.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.
Example The following example stops an output timing measurement with the
measurement name identifier called ‘MyOutputTiming’:
:PLUG:OTIM:STOP ‘MyOutputTiming’
:PLUGin:OTIMing:BREak
Syntax :PLUGin:OTIMing:BREak ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name to break/pause.
Description This command breaks/pauses a measurement addressed by the
measurement name identifier.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.
Example The following example breaks an output timing measurement with the
measurement name identifier called ‘MyOutputTiming’:
:PLUG:OTIM:BRE ‘MyOutputTiming’

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals