398 Keysight M8070A Programming Guide
5 SCPI Command Reference
:PLUGin:EDIagram:RESet
Syntax :PLUGin:EDIagram:RESet ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name to reset.
Description This command resets an eye diagram measurement addressed by the
measurement name identifier.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example The following example resets an eye diagram measurement addressed
with the measurement name identifier called ‘MyMeasurement’:
:PLUG:EDI:RES ‘MyMeasurement’
:PLUGin:EDIagram:STARt
Syntax :PLUGin:EDIagram:STARt ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name to start.
Description This command starts an eye diagram measurement addressed by the
measurement name identifier.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example The following example starts an eye diagram measurement addressed with
the measurement name identifier called ‘MyMeasurement’:
:PLUG:EDI:STAR ‘MyMeasurement’
:PLUGin:EDIagram:STEP
Syntax :PLUGin:EDIagram:STEP ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name to step.
Description This command allows you to step through an eye diagram measurement,
addressed by the measurement name identifier, that was stopped using
the BREak command.
This SCPI is applicable for M8041A, M8051A and M8062A.