410 Keysight M8070A Programming Guide
5 SCPI Command Reference
:PLUGin:EDIagram:FETCh[:RESult]:SCOunt?
Syntax :PLUGin:EDIagram:FETCh[:RESult]:SCOunt? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
Description This command returns the sample count.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example :PLUG:EDI:FETC:SCO? ‘MyMeasurement’
:PLUGin:EDIagram:FETCh[:RESult]:SNRatio?
Syntax :PLUGin:EDIagram:FETCh[:RESult]:SNRatio? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
Description This command returns signal-to-noise ratio which is a measurement of the
signal difference between 1 level and 0 level in relation to the rms value of
1-level noise + rms value of 0-level noise.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example :PLUG:EDI:FETC:SNR? ‘MyMeasurement’
:PLUGin:EDIagram:FETCh[:RESult]:WIDTh?
Syntax :PLUGin:EDIagram:FETCh[:RESult]:WIDTh? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
Description This command returns the calculated eye width which is horizontal
measurement of the eye opening at a specified BER Threshold.It can be
either at the eye crossing point (CROssing) or custom defined (CUStom).
This SCPI is applicable for M8041A, M8051A and M8062A.
Example :PLUG:EDI:FETC:WIDT? ‘MyMeasurement’