466 Keysight M8070A Programming Guide
5 SCPI Command Reference
:SYSTem:DCINterface[:PROGram]:SELected?
Syntax :SYSTem:DCINterface[:PROGram]:SELected?
Description This query returns the DUT Control Interface script that is currently in use.
If the DUT Control Interface is not using a script, an empty string is
returned.
Example :SYSTem:DCINterface:PROGram:SELected?
:SYSTem:DCINterface:EXEcute[:INIT]
Syntax :SYSTem:DCINterface:EXEcute[:INIT] ‘Location’[,“ArgumentsForInit”]
Input
Parameters
‘Location’: ‘*.Lane*’
Description This command matches the DUT Control Interface hook function
DUT_Init(location, argument).
Sending this command results in executing the function DUT_Init with the
given parameters if it is implemented by the script that is currently in use
(see syst:dcin:load).
The Location argument shall be one of the locations defined by the scripts
DUT_getLocations, but as full system location identifier.
For example, if,DUT_getLocations defines the locations "Lane1" and
"Lane2", then valid Location arguments are "DCI.Lane1" and "DCI.Lane2"
The argument string is not checked anyway, but simply passed to the
script implementation of DUT_Init.
Example :SYSTem:DCINterface:execute:init "DCI.Lane1"

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals