TRIGger:DLOG:CURRent:SLOPe POSitive|NEGative, (@<chanlist>)
TRIGger:DLOG:CURRent:SLOPe? (@<chanlist>)
TRIGger:DLOG:VOLTage:SLOPe POSitive|NEGative, (@<chanlist>)
TRIGger:DLOG:VOLTage:SLOPe? (@<chanlist>)
Sets the slope of the signal.๎œœ Applies when the data logger trigger source is set to a level.
POSitive specifies a rising slope of the output signal.
NEGative specifies a falling slope of the output signal.
Parameter Typical Return
POSitive|NEGative, *RST POSitive POS or NEG
Sets the current slope to falling edge: TRIG:DLOG:CURR:SLOP NEG, (@1)
Sets the voltageslope to falling edge: TRIG:DLOG:VOLT:SLOP NEG, (@1)