Kinco FD5 AC series servo driver user manual
Chatper 9 Servo panel parameter list
111
Chatper 9 Servo panel parameter list
The EASY group allows users to quickly set commonly used control parameters.
Table 9-1 EASY parameters
Panel
address
Internal
address
Name
Description
Defaults
Range
R/W/S
EA00
2FF00108
Stores control ring
parameters
Store control ring parameters (excluding
motor parameters)
1, store all configuration parameters set
10. Initialize all configuration parameters
0
0-255
RW
EA01
30410110
EASY motor Model
Configuration motor model
404b
/
RWS
EA02
30410208
EASY instruction type
Control instructions can be configured
quickly by setting the instruction type.
Note: Changing the instruction type will
change the working mode and the
definition of the IO port.
0: Dual-pulse mode CW/CCW
1: pulse direction mode P/D
2: A/B phase pulse control mode
8: Communication control mode
When the instruction type is set to 0-2,
corresponding to working mode -4, DIN
will be configured to factory Settings.
When the instruction type is set to 8,
DIN4 and DIN5 are defined as positive
limit and negative limit respectively,
DIN7 is defined as origin mode, working
mode and control word are controlled by
communication.
1
0~8
RWS
EA03
25080110
Electronic gear
molecule [0]
This parameter is valid when EA02 is
written to 0-2.
The value is displayed in decimal by
default. Values over 10000 are displayed
in hexadecimal.
Note: See Table 4 for the decimal and
hexadecimal display methods.
1000
32767~
-32768
RWS
EA04
25080210
Electronic gear
denominator [0]
1000
1~3276
7
RWS
EA05
30410410
The simulated speed
coefficient under
EASY
Set the analog speed factor
11
/
RWS
EA06
30410310
EASY application
Settings
Digit tube from units to thousands (digit
tube from right to left) represents:
Bits: Load type, which affects control
ring parameters
0: no load
1: Flexible load (such as belt, etc.)
2: Rigid load (such as ball screw)
Tens: applications that affect control ring
parameters
0: point-to-point mode (positioning
control)
1: CNC mode (interpolation control)
2: master/slave mode
Hundred position: Set the limit switch
0: Use the current limit switch setting
1020
/
RWS