Kinco FD5 AC series servo driver user manual Chapter 1 Servo system model and configuration description
10
1.4 Motor nameplate description
Figure 1-4 Motor nameplate description
1.5 Servo drive specifications
Model
FD425-□F-000
FD435-□A-000
FD625-□A-000
Power
supply
Power supply
1PH,200-240VAC±10% 50/60Hz±3HZ
(750W 7A)
(200W 3A)
1PH,3PH, 200-240VAC±10%
50/60Hz±3HZ 14.0A
3PH, 380-415VAC±10%
50/60Hz±3HZ 12.0A
Logic power supply
No separate logic power supply
200-240VAC±10% 50/60Hz±3HZ 0.5A
Power
supply
Maximum continuous
output current (rms)
5A
10A
7A
PEAK current (PEAK)
18Ap
27.5Ap
25Ap
Fedback signal
Photoelectric single-turn encoder;
Single-loop communication type magnetoelectric encoder;
Photoelectric multi-turn communication absolute value encoder;
Dynamic braking
FD425 Drive has no built-in braking resistorFD435 built-in 100Ω20W limited power FD625 built-in 300Ω
20W limited power
If the actual power exceeds the limit power, an external braking resistor is required (depending on the operating
conditions, mainly used in the occasions of quick start and stop)
Dynamic braking voltage
absorption point
DC380V±5V
DC380V±5V
DC680V±5V
Overvoltage alarm
DC400V±5V
DC400V±5V
DC700V±5V
Undervoltage alarm
DC200V±5V
DC200V±5V
DC400V±5V
Cooling method
Forced cooling
WeightKG
0.881
1.5
Position control
Mode
Order control
method
External pulse input control
Use DIN signals to control the 8-segment position
Communication Settings internal object parameter control
Order
smoothing
method
Low-pass filtering (internal parameter setting)
S-curve smoothing and filtering (internal parameter setting in 1 mode)
Pulse order
method
Pulse + direction, CCW+CW, A phase + B phase
Maximum
input pulse
frequency
Differential transmission modeup too 4MHzOpen collector transmission mode500KHz
Electronic gear
ratio
Setting range: Gear factor-3276832767Gear divider132767
1/50≤|Gear factor/Gear divider|≤50
Torque limit
Internal parameter setting
Feedforward
gain
0~100.0%Set by internal parameter
Position loop
sampling
frequency
2KHz