Kinco FD5 AC series servo driver user manual
Chatper 5 Kincoservo+ user guide
56
Click Open File to select a parameter settings file (.cdi). The parameter settings appear in the window.
Click Write to Controller to get the Check Value and Result. The “False” Result means the value has not been written successfully,
probably because the object doesn’t exist in the controller.
Click Save in EEPROM and Reboot to activate all parameters.
Note
Before writing the settings to the drive, unenable the drive, if the drive is enabled, some objects
cannot be successfully written.
5.5 Digital IO function
Click menu item Controller->Digital IO Functions or click the button . The following window
appears. Function and polarity are shown. Shown as default function and polarity.
Figure 5-8 Digital IO
5.5.1 Digital input
Figure 5-9 Digital input
Function:Click to select Din function setting click to delete the DIN function
Real
:
Shows the real digital input hardware status.
Actual input: Displays the actual digit input status
Polarity: indicates a high level input, and the effective input is 1; indicates a low level input, and the effective input
is 1.
Real:Shows the real digital input hardware status.
means “active”, logic status of the digital input is 1; means“not inactive”, logic status of the digital input is 0.
Table 5-2 Digital input function
Controller enabling
1: Enable controller = Din control word selection(2020.0F)
0: Disable controller = 0x06