Kinco FD5 AC series servo driver user manual Chapter 3 Servo system interface and wiring
37
Ordinary pulse input wiring
example
PNP Wiring method
High-speed pulse input wiring
example
NPN wiring method
High-speed pulse input wiring
example
PNP wiring method
3.4.4 Brake connection
Table 3-13 Brake connection example
Instruction
The driver's default OUT2 is brake control port, and it needs to be connected to
an external relay to control the motor brake
The brake coil of the motor has no polarity.
The 24V output power of driver X1 is not enough to control the brake, so an
external 24V is needed as the brake power supply
Brake connection example