Kinco FD5 AC series servo driver user manual
Chatper 5 Kincoservo+ user guide
53
Figure 5-2 Communication setting
Select the right COM port (if its not shown click the Refresh button), baud rate and COM ID (Node ID),
and then click the "OPEN buton.
Once communication has been established with the controller, communication can be opened or closed by
clicking the button .
5.1.4 Node ID and baud rate
The drive station number can be set through the menu bar "Drive" -> "Drive Property".
Table 5-1 note ID and baud rate
Panel address
Internal address
Type
Name
Value
Unit
D5.01
100B.00
Uint8
Node_ID
1~127
DEC
D5.02
2FE0.00
Uint16
RS232_baudrate
Panel setting Baudrate
540 19200
270 38400
90 115200
Baud
Note
The device station number and baud rate take effect only after the control parameters are stored and the
drive is restarted.
5.1.5 Objects (adddeletehelp)
Open any window with an object list, move the mouse pointer to the object item and right click. Thefollowing selection window
appears:
Click Add and double click the required object from the Object Dictionary. The selected object is then added to the list.
Click Delete. The selected object is removed from the list.
Click Help to read a description of the selected object in the Object Dictionary.
5.2 Init save reboot