Kinco FD5 AC series servo driver user manual Chapter 3 Servo system interface and wiring
35
3.4.1 Digital signal input
Table 3-10 Digital input wiring example
Digital input port maximum input frequency: 1KHz
High level input voltage range 12.5-30V, low level input voltage range 0-5V
The driver internal 24V output can be used as a pull-up power supply
Example of digital input wiring
①
When the upper computer is the
relay output
Digital input wiring example
②
When the host computer is open
collector output
3.4.2 Digital signal output
Table 3-11 Digital output wiring example
OUT1/OUT2 is open collector output
,
MAX voltage DC30V
,
MAX current 100mA
OUT3-OUT5 is single-ended output
,
MAX voltage DC30V
,
MAX current 30mA
The drive’s internal 24V output can be used as a pull-up power supply
When OUT3-OUT5 use PNP wiring, only one of them can be used
Digital input wiring
example①
When the host
computer is relay input