Kinco FD5 AC series servo driver user manual Chapter 3 Servo system interface and wiring
24
Figure 3-5 FD625 external connection
Table 3-1 External system installation description
Molded case circuit
breakers
(MCCB)
In the event of overcurrent, short circuit, or undervoltage, the circuit breaker automatically shuts off the
power supply, thus protecting the circuit and drive equipment from damage. Note that the protection
parameters that match the drive parameters are set.
Effectively filter out external interference and improve the anti-interference ability of power supply
circuit.
Use the air ac electromagnetic contactor to turn off the power supply and install the surge suppressor
recommended by the manufacturer of the electromagnetic contactor to effectively prevent the reverse
ELECTRO motive force.
Charging indicator light will not go out immediately after the power is cut off due to the charging
capacitor in the internal circuit of the drive. Please make sure that the charging indicator is off or the
voltage value of the dc bus voltage of the drive is below 36V before contacting the power terminal
Table 3-2 Recommended circuit breaker models
Table 3-3 Recommended noise filter models
Single phase 120/250VAC,16A
Single phase 120/250VAC
,
16A
Three-phase 275/480VAC
,
16A
Three-phase 275/480VAC,16A