INFORMATION ABOUT OPTIONAL
COMPONENTS
11
159
EN
11.6 3rd + 4th PTO (configurations)
F
ig. 11.32
Hydraulic pumps on the 3rd and 4th PTO can be installed at the
same time.
In some configurations, there is also the centering ring
C
on the
4th PTO.
Important
•
For disassembly or installation, refer to Par. 11.4, Par.
11.5 e Par. 11.6.
•
Always replace the gasket of the rings B and C and
flanges D and K at each assembly.
•
Lubricate the gear H w
ith oil.
Fig. 11.33