13: Maintenance
SLC™ 8000 Advanced Console Manager User Guide 280
To save the current SLC configuration to a selected location:
admin config save <Config Name> location
<local|ftp|sftp|nfs|cifs|usb|sdcard> [nfsdir <NFS Mounted Dir>] [usbport
<U1|U2>]
To rename a saved configuration:
admin config rename <Config Name> location <local|nfs|cifs|usb|sdcard>
[nfsdir <NFS Mounted Dir>] [usbport <U1|U2>]
To delete a saved configuration:
admin config delete <Config Name> location <local|nfs|cifs|usb|sdcard>
[usbport <U1|U2>]
To list the configurations saved to a location:
admin config show <local|ftp|sftp|nfs|cifs|usb|sdcard> [nfsdir <NFS
Mounted Dir>] [usbport <U1|U2>]
Displays a checksum for the current configuration to determine if the configuration has
changed:
admin config checksum
Copies the current configuration (or optionally, a configuration from another location) to
the other bank (for dual-boot SLCs):
admin config copy <current|Config Name>
[location <local|nfs|cifs|usb|sdcard>
[nfsdir <NFS Mounted Directory>] [usbport <U1|U2>] ]
To set the acceptable range for the internal temperature sensor (an SNMP trap is sent if the
temperature is outside of this range):
set temperature <one or more parameters>
Parameters
low <Low Temperature in C. or F.>
high <High Temperature in C. or F.>
calibrate <Temperature Calibration in C. or F.|cancel>
Note: The calibration offset will be applied one hour after setting the value.
To display the acceptable range and current reading from the internal temperature sensor:
show temperature