13: Maintenance
SLC™ 8000 Advanced Console Manager User Guide 287
3. Click the Run Diagnostics button. The Maintenance > Diagnostics page displays.
Host Lookup Select to verify that the SLC 8000 advanced console manager can resolve the host
name into an IP address (if DNS is enabled). If selected, also enter a host name in the
corresponding Hostname field,
Ping Select to verify that the host is up and running. If selected, also do the following:
Enter a host name in the corresponding Hostname field
Specify Ethernet Port (Both, Eth1 or Eth2)
Check if the IPv6 version of ping should be used.
Send Packet This option sends an Ethernet packet out one of the Ethernet ports, mainly as a network
connectivity test. For UDP, the number of times the string is sent is equal to the number
of packets sent. For TCP, the number of times the string is sent may (or may not) be
equal to the number of packets sent, because TCP controls how data is packetized and
sent out. Enter the following:
Protocol: Select the type of packet to send (TCP or UDP).
Hostname: Specify a host name or IPaddress of the host to send the packet to.
Port: Specify a TCP or UDP port number of the host to send the packet to.
String: Enter a set of up to 64 characters. The string is encapsulated in the packet (so
you could use a network sniffer to track the packet and, by looking at its contents,
verify that it was sent).
Count: The count is the number of times the string is sent.
Loopback Specify loopback information:
Device Port
Select either an Internal or External test
Note: The External test is currently not supported for USB device ports
SLC Internals Select to display information on the internal memory, storage and processes of the SLC
8000 advanced console manager.
USB Devices Select to display information about USB buses and the devices connected to them,
including a mapping between a USB device and the SLC ports.

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm

Related product manuals