15: Command Reference
SLC™ 8000 Advanced Console Manager User Guide 385
show vpn
Syntax
show vpn
Description
Shows the settings for the IPsec VPN tunnel.
Parameters
Display all VPN settings and current status:
show vpn [email <Email Address>]
Display detailed VPN status:
show vpn status [email <Email Address>]
Display VPN logs:
show vpn viewlog [numlines <Number of Lines] [email <Email Address>]
Display RSA public key of the SLC:
show vpn rsakey
set temperature
Syntax
set temperature
Description
Sets the acceptable range for the internal temperature sensor (an SNMP trap is sent if the
temperature is outside of this range). Temperatures can be entered in either Celsius or
Fahrenheit; to indicate a temperature is Fahrenheit, append the degrees with an ‘F’, i.e., “75F”.
Parameter
set temperature <one or more parameters>
Parameters: low <Low Temperature in C. or F.>
high <High Temperature in C. or F.>
calibrate <Temperature Calibration in C. or F.|cancel>
Note: The calibration offset will be applied one hour after setting the value.
Description
Displays the acceptable range and the current reading from the internal temperature sensor.

Table of Contents

Other manuals for Lantronix SLC 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 and is the answer not in the manual?

Lantronix SLC 8000 Specifications

General IconGeneral
Rack mountingYes
Console portRJ-45
Serial ports quantity48
USB 2.0 ports quantity2
AC input voltage120-230 V
Power source typeAC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Weight5030 g
Dimensions (WxDxH)436.9 x 304.8 x 43.18 mm

Related product manuals