Firmware 05.00 - DMS 4.2 EN - 02/2010 L 1011
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_Odometer_1
Outputs
Parameter
Identifier
Data type
Value/meaning
dnPosOut_1_p
...
dnPosOut_8_p
DINT
Detected positions
dnDeltaPos_12_p
dnDeltaPos_23_p
dnDeltaPos_34_p
...
dnDeltaPos_18_p
DINT
Calculated distances between the detected positions
dnDeltaPos_12_p = Distance between dnPosOut_1_p and dnPosOut_1_p
dnDeltaPos_23_p = Distance between dnPosOut_2_p and dnPosOut_3_p
dnDeltaPos_34_p = Distance between dnPosOut_3_p and dnPosOut_4_p
...
dnDeltaPos_18_p = Distance between dnPosOut_1_p and dnPosOut_8_p
wLastMeasure
WORD
Memory location number (1 ... 8) of the last measurement
Parameter Possible settings Info
C01020
Memory size
Lenze setting: 7 measurements
1 1 measurement
2 2 measurements
... ...
7 7 measurements
C01021
Memory type
Lenze setting: No ring buffer
0No ring buffer
1Ring buffer
C01022
Input selection
Lenze setting: Pos input
0Pos input
1V input
C01023
Edge selection
Lenze setting: HIGH edge
0High edge
1Low edge
2 High and low edge