Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 587
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00003
C00003
C00005
Parameter | Name:
C00003 | Status of last device command
Data type: UNSIGNED_8
Index: 24572
d
= 5FFC
h
Status of the device command carried out last (C00002).
Note:
Before switching off the supply voltage after carrying out a device command, check whether the device command
has been carried out successfully via the status display!
Drive control (DCTRL)
: Device commands
Selection list (read only) Info
0 Successful Device command has been carried out successfully.
1 Command unknown Device command is implausible or not known in the
system.
2 No access Access for requested device command is not approved.
3 Time-out Device command could not be processed in the defined
time (time-out).
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00005 | Application selection
Data type: UNSIGNED_16
Index: 24570
d
= 5FFA
h
Selection of the technology application
Selection list (Lenze setting printed in bold) Info
0 Wiring has changed This display appears if the FB interconnection has been
changed in the application level using the FB Editor.
1000 Actuating drive speed This technology application is used to solve speed-
controlled drive tasks, e.g. conveying belts.
2000 Table positioning This technology application is used to solve position-
controlled drive tasks which are usually controlled by a
higher-level control system using a fieldbus.
3000 Switch-off positioning As of version 04.00.00
This technology application is used to solve speed-
controlled drive tasks which require a pre-switch off or
stopping at certain positions, e.g. roller conveyors and
conveying belts. This is implemented by connecting
switch-off sensors.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1