8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_PCTRL_1
1040 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.118.5 Deactivation of the process controller
Setting the input bInAct to TRUE deactivates the process controller. As a result, the PID
output, the I component, and the ramp function generator are reset to "0". A setpoint
defined in operating modes 1 + 4 via the input nNSet_a, however, will still be output.