EasyManua.ls Logo

Lenze 8400 HighLine C Series - 14.1.74 L_GainOffsetPhiP_1

Lenze 8400 HighLine C Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 969
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_GainOffsetPhiP_1
14.1.74 L_GainOffsetPhiP_1
This FB can amplify an angle signal and add an offset to it afterwards.
The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow.
Gain and offset are selected via parameters.
The value provided at the dnOut_p output is internally limited to ±2
31
-1.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
dnIn_p
DINT
Input signal
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
Internal limitation to ±2
31
-1 (±2147483647)
Parameter Possible settings Info
C00678/1
-2147483647 Incr. 2147483647 Offset
Lenze setting: 0 incr.
C00678/2
-2147483647 2147483647 Gain factor
Lenze setting: 65536
/B*DLQ2IIVHW3KL3B
GQ,QBS GQ2XWBS
2IIVHW*DLQ
& &

r

dnOut_p dnIn_p Gain factor()Offset+=
efesotomasyon.com - Lenze