8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_PT1_2
1042 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.120 L_PT1_2
This FB filters and delays analog signals.
The filter time constant T can be set under C00250/1
.
The gain is defined with V
p
= 1.
Inputs
Outputs
Parameter
Function
[14-41] Filter time constant T of the first-order delay element
Identifier
Data type
Information/possible settings
nIn_a
INT
Input signal
Identifier
Data type
Value/meaning
nOut
INT
Output signal
Parameter Possible settings Info
C00250/1 0.01 s 50.00 Filter time constant
When 0.01 s is set, the filter is not
active.
Lenze setting: 20.00 s
/B37B
)LOWHUWLPH
&
Q,QBD Q2XWBD
T
V=1
p
t