8400 HighLine | Parameter setting & configuration
I/O terminals
Analog terminals
242 L Firmware 05.00 - DMS 4.2 EN - 02/2010
6.3.3 Internal interfaces | System block "LS_AnalogInput"
The LS_AnalogInput system block maps the analog inputs in the FB editor.
Output
DIS code | data type
Value/meaning
nIn1_a
C00033/1 | INT
Analog input 1
Scaling:
±2
14
±10 V for use as voltage input
+2
14
+20 mA for use as current input
bCurrentErrorIn1
BOOL
Status signal "Current input error"
Only when analog input 1 is used as current input.
Application: Cable-breakage monitoring of the 4 ...20 mA circuit.
TRUE |I
AIN1
| < 4 mA
nIn2_a
C00033/2 | INT
Analog input 2
Scaling:
±2
14
±10 V for use as voltage input
+2
14
+20 mA for use as current input
bCurrentErrorIn2
BOOL
Status signal "Current input error"
Only when analog input 2 is used as current input.
Application: Cable-breakage monitoring of the 4 ...20 mA circuit.
TRUE |I
AIN2
| < 4 mA
/6B$QDORJ,QSXW
;
E&XUUHQW(UURU,Q
Q,QBD
$8
$5
$,
$8
$,*$282,282,
&
&
&
'
$
&
2IIVHW *DLQ
& &
)LOWHUWLPH
&
&
&[
E&XUUHQW(UURU,Q
Q,QBD
'
$
&
2IIVHW *DLQ
& &
)LOWHUWLPH
&
&
&[
&
& (UURUUHDFWLRQ
& (UURUUHDFWLRQ