EasyManua.ls Logo

Lenze 8400 HighLine C Series - C00059 | Appl.: Reference frequency C11; C00061 | Heatsink temperature; C00064 | Device utilisation (Ixt); C00065 | 24 V supply voltage

Lenze 8400 HighLine C Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 599
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00059
C00059
C00061
C00064
C00065
C00066
Parameter | Name:
C00059 | Appl.: Reference frequency C11
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display of the field frequency which corresponds to the reference speed set in C00011.
Display range (min. value | unit | max. value)
0.00 Hz 1300.00
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_16
Index: 24514
d
= 5FC2
h
Display of the current heatsink temperature
Display range (min. value | unit | max. value)
-50 °C 150
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00064 | Device utilisation (Ixt)
Data type: INTEGER_16
Index: 24511
d
= 5FBF
h
Display of the device utilisation Ixt in different time resolutions
If the value displayed here exceeds the threshold set in C00123
, the fault message "OC5: Device overload (Ixt)"
is output and the fault response set in C00604
is executed (default setting: "Warning").
Display range (min. value | unit | max. value)
0.00 % 250.00
Subcodes Info
C00064/1 Device utilisation (Ixt)
Maximum value of the pulse utilisation (C00064/2)
and permanent utilisation (C00064/3).
C00064/2 Device utilisation (Ixt) 15s
Pulse utilisation over the last 15 seconds (only for
loads >160 %).
C00064/3 Device utilisation (Ixt) 3 min
Permanent utilisation over the last 3 minutes.
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00065 | 24 V supply voltage
Data type: INTEGER_16
Index: 24510
d
= 5FBE
h
Display of the 24V supply voltage for the supply of the control electronics
Note:
The 24 V supply for the control electronics is either provided by an external supply or by the controller itself if it is
connected to the mains voltage.
Display range (min. value | unit | max. value)
0.0 V 3276.7
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00066 | Thermal motor load (I²xt)
Data type: INTEGER_16
Index: 24509
d
= 5FBD
h
Display of the thermal motor load being detected sensorless via a motor model
If the value displayed here exceeds the threshold set in C00120
, the fault message "OC6: Thermal motor overload
(I2xt)" is output and the fault response set in C00606
is executed (default setting: "Warning").
Display range (min. value | unit | max. value)
0.00 % 199.99
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100