Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 709
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00823
C00823
C00824
Parameter | Name:
C00823 | L_DigitalLogic_2: Truth table
Data type: UNSIGNED_8
Index: 23752
d
= 5CC8
h
FB L_DigitalLogic_2: Parameterisation of the truth table
Selection list
0False
1True
Subcodes Lenze setting Info
C00823/1 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=0
C00823/2 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=0
C00823/3 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=0
C00823/4 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=0
C00823/5 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=1
C00823/6 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=1
C00823/7 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=1
C00823/8 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=1
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00824 | L_DigitalLogic5_1: Function
Data type: UNSIGNED_8
Index: 23751
d
= 5CC7
h
FB L_DigitalLogic5_1: Selection of the internal logic interconnection
Selection list (Lenze setting printed in bold) Info
0bOut = 0
1bOut = 1
2 bOut = f (truth table) The truth table parameterised in C00825
is used.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
efesotomasyon.com - Lenze