Firmware 05.00 - DMS 4.2 EN - 02/2010 L 1019
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_OffsetGainPhiP_2
14.1.107 L_OffsetGainPhiP_2
This FB can add an offset to an angle signal and amplify it afterwards.
The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow.
Offset and gain are selected via parameters.
The value provided at the dnOut_p output is internally limited to ±2
31
-1.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
dnIn_p
DINT
Input signal
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
Internal limitation to ±2
31
-1 (±2147483647)
Parameter Possible settings Info
C00673/2
-2147483647 Incr. 2147483647 Offset
Lenze setting: 0 incr.
C00674/2
-2147483647 2147483647 Gain factor
Lenze setting: 65536
/B2IIVHW*DLQ3KL3B
GQ,QBS GQ2XWBS

r

2IIVHW *DLQ
& &
dnOut_p dnIn_p Offset+()Gain factor=