Firmware 05.00 - DMS 4.2 EN - 02/2010 L 789
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01903
C01903
C01905
C02580
C02581
Parameter | Name:
C01903 | Diagnostics X6: Change baud rate
Data type: UNSIGNED_8
Index: 22672
d
= 5890
h
New baud rate determination at the diagnostic interface X6
Selection list (Lenze setting printed in bold)
0 Ignore changes
1Negotiate baud rate
; Read access ; Write access CINH PLC STOP ; No transfer ; COM MOT Scaling factor: 1
Parameter | Name:
C01905 | Diagnostics X6: Act. baud rate
Data type: UNSIGNED_32
Index: 22670
d
= 588E
h
Current baud rate at the diagnostic interface X6
Display range (min. value | unit | max. value)
0 Bd 3000000
; Read access Write access CINH PLC STOP ; No transfer ; COM MOT Scaling factor: 1
Parameter | Name:
C02580 | Holding brake: Operating mode
Data type: UNSIGNED_8
Index: 21995
d
= 55EB
h
Selection of the operating mode for holding brake control
Holding brake control
Selection list (Lenze setting printed in bold) Info
0 Brake control off No holding brake is used. The internal control system is
switched off.
11 Manually controlled The holding brake is released and applied via a control bit
in the MCK control word.
12 Autom. controlled The holding brake is released and applied automatically
via speed setpoint comparisons.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C02581 | Holding brake: Speed threshold
Data type: INTEGER_16
Index: 21994
d
= 55EA
h
Speed setpoint threshold and hysteresis for automatic holding brake control
Holding brake control
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C02581/1 5.00 % Holding brake: Switching threshold
Switching threshold of the speed setpoint from which
on the holding brake is released/applied
automatically.
C02581/2 1.00 % Holding brake: Hyst.release
Hysteresis for holding brake release.
Release threshold = switching threshold + release
hysteresis
C02581/3 1.00 % Holding brake: Hyst. close
Hysteresis for holding brake application.
Application threshold = switching threshold -
application hysteresis
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100