Page #890 background image
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_Arithmetik_3
890 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.16 L_Arithmetik_3
This FB can combine two analog signals arithmetically.
The arithmetic function is selected in C00650/1
.
All internal intermediate results and the value output at the nOut_a output are
internally limited to ±32767.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
Internal limitation to ±32767 (±199.99 %)
Parameter Possible settings Info
C00650/1 Function selection
0
1
2
3
4 When the denominator has the
value "0", it will be set to "1".
5
/B$ULWKPHWLNB
Q,QBD Q2XWBD
Q,QBD
r
,Q
,Q,Q
,Q
,Q,Q
,Q,Q
,Q

_,Q_
,Q
2XW
,Q
,Q
&
n
Out_a nIn1_a=
n
Out_a nIn1_a nIn2_a+=
n
Out_a nIn1_a nIn2_a=
nOut_a
nIn1_a nIn2_a
16384
----------------------------------------=
nOut_a
nIn1_a
nIn2_a
-------------------- -
164=
nOut_a
nIn1_a
16384 nIn2_a
----------------------------------------
16384=
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 HighLine C Series and is the answer not in the manual?

Lenze 8400 HighLine C Series Specifications

General IconGeneral
BrandLenze
Model8400 HighLine C Series
CategoryInverter Drive
LanguageEnglish

Related product manuals