Firmware 05.00 - DMS 4.2 EN - 02/2010 L 951
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_DigitalLogic_1
14.1.60 L_DigitalLogic_1
This FB provides a binary output signal which is generated by the logic combination of the
input signals. It is also possible to provide a constant binary value that is independent of
the input signals.
Output of a fixed binary value
Logical ANDing of the inputs
Logical ORing of the inputs
Output depending on the combination of the input signals
Inputs
Outputs
Identifier
Data type
Information/possible settings
bIn1
BOOL
Input signal 1
bIn2
BOOL
Input signal 2
bIn3
BOOL
Input signal 3
Identifier
Data type
Value/meaning
bOut
BOOL
Output signal
/B'LJLWDO/RJLFB
E,Q
!



E2XW
&
&
&
&
E,Q
E,Q
&