8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00470
662 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00470
C00471
Parameter | Name:
C00470 | LS_ParFree_b
Data type: UNSIGNED_8
Index: 24105
d
= 5E29
h
SB LS_ParFree_b: Setting of the signal level to be output
Selection list
0False
1True
Subcodes Lenze setting Info
C00470/1 0: FALSE Signal level for output bPar1 ... bPar32
C00470/...
C00470/32
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00471 | LS_ParFree
Data type: UNSIGNED_16
Index: 24104
d
= 5E28
h
SB LS_ParFree: Setting of the words to be output
Setting range (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded:
Bit 0 Bit0
... ...
Bit 15 Bit15
Subcodes Lenze setting Info
C00471/1 0 Value for output wPar1 ... wPar32
C00471/...
C00471/32
; Read access ; Write access CINH PLC STOP No transfer COM MOT