Firmware 05.00 - DMS 4.2 EN - 02/2010 L 111
8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Defining current and speed limits
How to adapt the peak current limitation:
V/f characteristic control (VFCplus):
Reduce the slip compensation with C00021
.
V/f control (VFCplus + encoder):
Reduce the slip limitation to twice the rated motor slip with C00971
.
Reduce the V
min
boost in C00016.
Sensorless vector control (SLVC):
Reduce the slip compensation with C00021
.
Reduce the limitation of the torque in motor mode via nTorqueMotLimit_a
(C00728/1
) and the limitation of the torque in generator mode via
nTorqueGenLimit_a (C00728/2
).
Servo control (SC):
Reduce the jerk limitation with C00274
.
Reduce the limitation of the torque in motor mode via nTorqueMotLimit_a
(C00728/1
) and the limitation of the torque in generator mode via
nTorqueGenLimit_a (C00728/2
).