Firmware 05.00 - DMS 4.2 EN - 02/2010 L 213
8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Internal interfaces | system block "LS_MotorInterface"
bFlyingSyncActive
BOOL
"Flying restart function active" status signal
Flying restart function
( 171)
TRUE Flying restart function is active
bHlgLoad
BOOL
Control signal for an additional loading function of the ramp function generator
L_NSet_1
.bExternalCINH
To enable the ramp function generator to follow automatically when the
controller is inhibited, for jerk-free setpoint connection.
TRUE Set the ramp function generator to a setpoint of nHlgSetValue_a
nHlgSetValue_a
INT
Setpoint for an additional loading function of the ramp function generator
L_NSet_1
.nCInhVal_a
For speed-controlled drive tasks, the current actual speed value (e.g. in case of an
active pulse inhibit, flying restart function, controller inhibit) is provided at this
output.
Scaling: 16384 100 % rated speed (C00011
)
bHlgStop
BOOL
Control signal for stopping the ramp function generator (L_NSet_1)
TRUE Stop the ramp function generator