C00481 LS_DisFree 24094 5E1E A 8 UNSIGNED_16 ;
C00482
LS_DisFree_a 24093 5E1D A 8 INTEGER_16 100 ;
C00483
LS_DisFree_p 24092 5E1C A 8 INTEGER_32 1 ;
C00488
L_JogCtrlEdgeDetect_1 24087 5E17 A 6 UNSIGNED_8 1 ;;
C00490
Position encoder selection 24085 5E15 E 1 UNSIGNED_8 1 ;;
C00495
Speed sensor selection 24080 5E10 E 1 UNSIGNED_8 1 ;;
C00496
Encoder evaluation procedure 24079 5E0F E 1 UNSIGNED_8 1 ;;;
C00497
Nact filter time constant 24078 5E0E A 2 UNSIGNED_16 10 ;;
C00517
User menu 24058 5DFA A 32 INTEGER_32 1000 ;;
C00560
Fan switching status 24015 5DCF A 2 UNSIGNED_8 1 ;
C00561
Fan failure 24014 5DCE A 2 UNSIGNED_8 1 ;
C00565
Resp. to mains phase failure 24010 5DCA E 1 UNSIGNED_8 1 ;;
C00566
Resp. to fan failure 24009 5DC9 E 1 UNSIGNED_8 1 ;;
C00567
Speed controller resp. limited 24008 5DC8 E 1 UNSIGNED_8 1 ;;
C00569
Resp. to peak current 24006 5DC6 A 1 UNSIGNED_8 1 ;;
C00570
Resp. to controller limitations 24005 5DC5 A 4 UNSIGNED_8 1 ;;
C00572
Brake resistor overload threshold 24003 5DC3 E 1 UNSIGNED_8 1 ;;
C00574
Resp. to brake resist. overtemp. 24001 5DC1 E 1 UNSIGNED_8 1 ;;
C00576
SC: Field feedforward control 23999 5DBF E 1 UNSIGNED_16 1 ;;
C00577
SC: Vp field weakening controller 23998 5DBE E 1 UNSIGNED_16 10000 ;;
C00578
SC: Tn field weakening controller 23997 5DBD E 1 UNSIGNED_16 10 ;;
C00579
Resp. to max. speed / output freq.
reached
23996 5DBC E 1 UNSIGNED_8 1 ;;
C00581
Resp. LS_SetError_x 23994 5DBA A 8 UNSIGNED_8 1 ;;
C00582
Resp. to heatsink temp. > shutdown
temp. -5°C
23993 5DB9 E 1 UNSIGNED_8 1 ;;
C00585
Resp. to motor overtemp. PTC 23990 5DB6 E 1 UNSIGNED_8 1 ;;
C00586
Resp. to encoder wire breakage 23989 5DB5 E 1 UNSIGNED_8 1 ;;
C00588
Resp. to max. speed at switch.
frequency
23987 5DB3 E 1 UNSIGNED_8 1 ;;
C00590
Resp. to switch. frequency red. 23985 5DB1 E 1 UNSIGNED_8 1 ;;
C00592
Resp. to CAN bus connection 23983 5DAF A 5 UNSIGNED_8 1 ;;
C00593
Resp. to CANx_IN monitoring 23982 5DAE A 3 UNSIGNED_8 1 ;;
C00594
Resp. to control word error 23981 5DAD A 2 UNSIGNED_8 1 ;;
C00595
MCK: Resp. to MCK error 23980 5DAC A 14 UNSIGNED_8 1 ;;
C00597
Resp. to motor phase failure 23978 5DAA E 1 UNSIGNED_8 1 ;;
C00598
Resp. to open circuit AINx 23977 5DA9 A 2 UNSIGNED_8 1 ;;
C00599
Motor phase failure threshold 23976 5DA8 E 1 INTEGER_16 100 ;;
C00600
Resp. to DC bus voltage 23975 5DA7 A 1 UNSIGNED_8 1 ;;
C00601
Delayed resp. fault: DC-bus
overvoltage
23974 5DA6 A 1 UNSIGNED_16 1000 ;;
C00602
Resp. to earth fault 23973 5DA5 E 1 UNSIGNED_8 1 ;;
C00604
Resp. to device overload (Ixt) 23971 5DA3 E 1 UNSIGNED_8 1 ;;
C00606
Resp. to motor overload (I²xt) 23969 5DA1 E 1 UNSIGNED_8 1 ;;
C00607
Resp. to high freq. DI12/67 reached 23968 5DA0 E 1 UNSIGNED_8 1 ;;
C00608
Resp. to maximum torque 23967 5D9F E 1 UNSIGNED_8 1 ;;
C00609
Resp. to maximum current 23966 5D9E E 1 UNSIGNED_8 1 ;;
C00620
System connection list: 16-bit 23955 5D93 A 75 UNSIGNED_16 1 ;;
C00621
System connection list: Bool 23954 5D92 A 127 UNSIGNED_16 1 ;;
C00622
System connection list: Angle 23953 5D91 A 12 UNSIGNED_16 1 ;;
C00630
L_Limit 1-2: Min/Max 23945 5D89 A 4 INTEGER_16 100 ;;
C00631
L_LimitPhi 1-3: Min/Max 23944 5D88 A 6 INTEGER_32 1 ;;
Code Name Index Data Access