9300 Servo PLC
Connection
3-26
9300ServoPLC EN 1.4
Possible axis synchronizations
Synchronization via system bus (CAN)by sync telegram
Synchronization via terminal by sync signal at terminal X5/E5
Tip!
The system block
CAN_Synchronization
must previously be entered into the control
configuration.
Synchronization via system bus:
The system bus must previously be correctly installed (see Part 3, Automation).
Synchronization via terminal:
The system block DIGITAL_IO must be entered into the control configuration.
Control mode
Code LCD
Possible settings
IMPORTANT
C
d
e
C
Lenze Choice
O
[C1121] Sync mode 0 0{1}2
0: Off
1: CAN Sync
2: Terminal Sync
CAN Sync source
0: Synchronization deactivated
1: Synchronizes the controllers on
the sync telegram of the system
bus
2: Synchronizes the controllers on
the sync signal of terminal X5/E5.
Synchronization time
After mains connection and the initialization time of the controller, additional time is needed for
synchronization.
The synchronization time depends on
the baud rate of the system bus,
the start time (input of the first sync telegram/signal),
the time between the sync telegrams/signals,
the sync correction factor (C0363),
the control mode (C1120)