9300 Servo PLC
Connection
3-7
9300ServoPLC EN 1.4
3.1.5.2 Parameter channels
Parameters are values that are stored in the Lenze drive controllers in a code position. Parameters
are set, for example, for one-off system settings or a change of materials in a machine.
Parameter are transmitted with a low priority.
Parameter channel 2
Parameter channel 1
write
read
read
write
Parameters
(Code)
Parameters
(Code)
HMI
PC
Abb. 3-2 Connection of devices through two parameter channels
With 2 parameter channels it is possible to connect of 2 different devices for parameter setting, e.g.
the simultaneous connection of a PC and an operating unit (see Abb. 3-2).
Tip for 9300 Servo PLC!
The blocks
L_ParRead / L_ParWrite
(from: LenzeDrive.lib) read and write access to other Lenze
devices is possible.