9300 Servo PLC
System blocks
2.13 Internal motor control (MCTRL_MotorControl)
2-64
9300ServoPLC EN 1.4
2.13.13.12 Plant speed monitoring N
Max
(MCTRL_bNmaxFault_b)
Purpose
Process monitoring
Function
A maximum plant speed can be entered under code C0596, independent of the direction of rotation.
The monitoring is released, if:
the actual speed exceeds the limit C0596
the actual speed is more than twice the value of C0011(n
max
).
Stop!
For active loads (e.g. hoists)make sure that no torque is applied atthe drive. Special,
plant-specific measures are required.
If the actual speed encoder fails, it is not ensured that this monitoring reacts.
Features:
LECOM no.: 200
Reaction: TRIP (cannot be modified)