9300 Servo PLC
Connection
3-32
9300ServoPLC EN 1.4
3.4.2 Description of the codes for the system bus
3.4.2.1 Baud-rate setting C0351
The following settings are possible:
C0351 Value [kBit/s]
0 500 (Lenze setting)
1 250
2 125
3 50
4 1000
Save changes with C0003.
The settings only become effective after the following actions:
Anewpower-on
A Reset-Node” command via the bus system (
^
3-22, CAN_ResetNode)
A Reset-Node through code C0358 (
^
3-22, CAN_ResetNode)
3.4.2.2 Defining a master in a drive group C0352
If information is exchanged between one drive and another in a drive group, without a higher-level
control system being present to provide the master function, then one drive controller must be
defined as the master.
The following assignments are valid:
C0352 = 0: drive is slave (factory setting)
C0352 = 1: drive is master
The master functionality is only required for the initialisation phase of the drive system.
The master effects a change of state from Pre-Operational to Operational.
An exchange of data through process-data objects is only possible in the Operational state.
(
^
3-36 C0359 bus status)
In addition, you can define a Boot-Up time for the master during the initialisation phase.
(
^
3-35 Boot-Up setting C0356/1)