9300 Servo PLC
System blocks
2.2 Automation interface (AIF1_IO_AutomationInterface)
2-4

9300ServoPLC EN 1.4
2.2 Automation interface (AIF1_IO_AutomationInterface)
2.2.1 Inputs_AIF1 (AIF1_IN)
Automation interface (module number 41)
This SB is used as an interface for input signals from plugged-in fieldbus modules (e.g. INTERBUS,
PROFIBUS-DP) for setpoint/actual values as binary, analog or phase-angle information.
• Theprocessimageis
– created in a cyclic task in a fixed time period of 10 ms
– created in an interval task within the time set for this task.
When the task is started, the process image is read and when the task is completed, the
task is written.
Tip!
Pleaseobserve thecorresponding OperatingInstructions for thefieldbusmodule that is plugged in.
16 Bit
16 Bit
AIF1_nInW 2_a
16
binary
signals
16 Bit
Low W ord
16 Bit
H ighW ord
16 Bit
AIF1_nInW 1_a
AIF1_bInB15_b
AIF1_bInB0_b
AIF1_dnInD 1_p
B y te 3 ,4
B y te 5 ,6
B y te 7 ,8
utom ation
In te rfa c e
Bit 0
Bit 15
Byte 1,2
AIF1_bInB14_b
AIF1_bInB2_b
AIF1_bInB31_b
AIF1_bInB16_b
AIF1_bInB30_b
AIF1_bInB17_b
. . .
C 0857
C 0856/1
C0856/2
C 0855/1
C 0855/2
C 0856/3
C 0136/3
AIF1_nInW 3_a
16 Bit
AIF1_wDctrlCtrl
. . .
AIF1_IN
16
binary
signals
AIF1_bC trlB 0_b
AIF1_bC trlQ uickstop_b
AIF1_bC trlTripR eset_b
AIF1_bC trlTripSet_b
AIF1_bC trlC Inhibit_b
AIF1_bCtrlDisable_b
AIF1_bC trlB 1_b
AIF1_bC trlB 2_b
AIF1_bC trlB 4_b
AIF1_bC trlB 5_b
AIF1_bC trlB 6_b
AIF1_bC trlB 7_b
AIF1_bC trlB 12_b
AIF1_bC trlB 13_b
AIF1_bC trlB 14_b
AIF1_bC trlB 15_b
16
binary
signals
Abb. 2-4 Inputs_AIF1 (AIF1_IN)