2.4 Automation interface (AIF3_IO_AutomationInterface)
2.4.1 Inputs_AIF3 (AIF3_IN)
Automation interface (module number 43)
This SB is used as an interface for input signals from plugged-in fieldbus modules (e.g. INTERBUS,
PROFIBUS-DP) for setpoint/actual values as binary, analog or phase-angle information.
• Theprocessimageis
– created in a cyclic task in a fixed time period of 10 ms
– created in an interval task within the time set for this task.
When the task is started, the process image is read and when the task is completed, the
task is written.
Tip!
Pleaseobserve thecorresponding OperatingInstructions for thefieldbusmodulethat is plugged in.
16 Bit
16 Bit
AIF3_nInW 1_a
16 Bit
Low W ord
16 Bit
H igh W ord
16 Bit
AIF3_nInW 3_a
AIF3_bInB0_b
AIF3_dnInD 1_p
B y te 3 ,4
B y te 5 ,6
B y te 7 ,8
AIF3_IN
Bit 0
Bit 15
......
B y te 1 ,2
16 Bit
AIF3_nInW 4_a
AIF3_nInW 2_a
AIF3_bInB1_b
AIF3_bInB14_b
AIF3_bInB15_b
AIF3_bInB16_b
AIF3_bInB17_b
AIF3_bInB30_b
AIF3_bInB31_b
A u to m a tio n
In te rfa c e
16
binary
signals
16
binary
signals
Abb. 2-8 Inputs_A IF3 (AIF3_IN)