9300 Servo PLC
System blocks
2.8 Drive control (DCTRL_DriveControl)
2-28
9300ServoPLC EN 1.4
2.8.3 Controller inhibit “ControllerInhibit (CINH)
The power output stages are disabled. All speed/current/position controllers are reset.
The function can be operated via 6 inputs:
Terminal X5/28 (FALSE = controller disable)
Control word
CAN1_wDctrlCtr
from SB CAN1_IN
Control word
AIF_wDctrlCtrl
from SB AIF1_IN
Control word C0135.B9
System variables
DCTRL_bCInh1_b
(VAR_INPUT)
System variables
DCTRL_bCInh2_b
(VAR_INPUT)
All inputs are linked by an OR-operation.
C0136/1 displays the control word C0135
2.8.4 TRIP-SET
The drive is operated in the state selected under C0581, and signals ExternalFault.
The function can be operated via 4 inputs:
Control word
CAN1_wDctrlCtr
from SB CAN1_IN
Control word
AIF_wDctrlCtrl
from SB AIF1_IN
Control word C0135.B10
System variables
DCTRL_bTripSet_b
(VAR_INPUT)
All inputs are linked by an OR-operation.
C0136/1 displays the control word C0135
2.8.5 TRIP-RESET
TRIP-RESET resets an active TRIP, provided that the cause of the fault has been removed. If the
cause of the fault is still active, there is no reaction.
The function can be operated via 4 inputs:
Control word
CAN1_wDctrlCtr
from SB CAN1_IN
Control word
AIF_wDctrlCtrl
from SB AIF1_IN
Control word C0135.B11
System variables
DCTRL_bTripReset_b
(VAR_INPUT)
All inputs are linked by an OR-operation.
The function can only be performed by a FALSE-TRUE transition of the signal resulting from
the OR operation.
C0136/1 displays the control word C0135
Tip!
If TRUE is present at one of the inputs, no FALSE-TRUE transition can occur in the resulting signal.