9300 Servo PLC
System blocks
2.3 Automation interface (AIF2_IO_AutomationInterface)
2-12
9300ServoPLC EN 1.4
2.3.2 Outputs_AIF2 (AIF2_OUT)
Automation interface (module number 42)
This SB is used as aninterface for output signalsto the plugged-in fieldbusmodules (e.g. INTERBUS,
PROFIBUS-DP) for setpoint/actual values as binary, analog or phase-angle information.
• Theprocessimageis
– created in a cyclic task in a fixed time period of 10 ms
– created in an interval task within the time set for this task.
When the task is started, the process image is read and when the task is completed, the
task is written.
Tip!
Pleaseobserve thecorresponding OperatingInstructions for thefieldbusmodule that is plugged in.
AIF2_OUT
Byte 1,2
Bit 0
Bit 15
Bit 0
Bit 31
B y te 7 ,8
B y te 5 ,6
A u to m a tio n
In te rfa c e
B y te 3 ,4
AIF2_dnO utD 1_p
16 Bit
Low W ord
16 Bit
H igh W ord
16 Bit
Low W ord
16 Bit
H igh W ord
AIF2_nO utW 1_a
AIF2_nO utW 2_a
Bit 0
Bit 15
A IF2_nO utW 3_a
A IF2_nO utW 4_a
Bit 15
A IF2_bFD O 0_b
A IF2_bFD O 15_b
...
A IF2_bFD O 16_b
A IF2_bFD O 31_b
...
A bb. 2-7 O utpu ts_AI F 2 ( A I F 2 _ O UT )