9300 Servo PLC
System blocks
2.3 Automation interface (AIF2_IO_AutomationInterface)
2-13
9300ServoPLC EN 1.4
VariableName DataType SignalType Address DIS DIS format Note
AIF2_nOutW1_a Integer analog %QW42.0 +100 % = +16384
AIF2_nOutW2_a Integer analog %QW42.1 +100 % = +16384
AIF2_nOutW3_a Integer analog %QW42.2 +100 % = +16384
AIF2_nOutW4_a Integer analog %QW42.3 +100 % = +16384
AIF2_bFDO0_b Bool binary %QX42.0.0
AIF2_bFDO1_b Bool binary %QX42.0.1
AIF2_bFDO2_b Bool binary %QX42.0.2
AIF2_bFDO3_b Bool binary %QX42.0.3
AIF2_bFDO4_b Bool binary %QX42.0.4
AIF2_bFDO5_b Bool binary %QX42.0.5
AIF2_bFDO6_b Bool binary %QX42.0.6
AIF2_bFDO7_b Bool binary %QX42.0.7
AIF2_bFDO8_b Bool binary %QX42.0.8
AIF2_bFDO9_b Bool binary %QX42.0.9
AIF2_bFDO10_b Bool binary %QX42.0.10
AIF2_bFDO11_b Bool binary %QX42.0.11
AIF2_bFDO12_b Bool binary %QX42.0.12
AIF2_bFDO13_b Bool binary %QX42.0.13
AIF2_bFDO14_b Bool binary %QX42.0.14
AIF2_bFDO15_b Bool binary %QX42.0.15
AIF2_bFDO16_b Bool binary %QX42.1.0
AIF2_bFDO17_b Bool binary %QX42.1.1
AIF2_bFDO18_b Bool binary %QX42.1.2
AIF2_bFDO19_b Bool binary %QX42.1.3
AIF2_bFDO20_b Bool binary %QX42.1.4
AIF2_bFDO21_b Bool binary %QX42.1.5
AIF2_bFDO22_b Bool binary %QX42.1.6
AIF2_bFDO23_b Bool binary %QX42.1.7
AIF2_bFDO24_b Bool binary %QX42.1.8
AIF2_bFDO25_b Bool binary %QX42.1.9
AIF2_bFDO26_b Bool binary %QX42.1.10
AIF2_bFDO27_b Bool binary %QX42.1.11
AIF2_bFDO28_b Bool binary %QX42.1.12
AIF2_bFDO29_b Bool binary %QX42.1.13
AIF2_bFDO30_b Bool binary %QX42.1.14
AIF2_bFDO31_b Bool binary %QX42.1.15
AIF2_dnOutD1_p Double integer position %QD42.0 1 revolution = 65536