9300ServoPLC EN 1.4
When certain telegrams have to be transmitted, a change is made to a different state:
from after Data (hex) Remarks
Pre-Operational Operational 01xx Process and parameterization data are active
Operational Pre-Operational 80xx only parameterization data are active
Operational Initialisation 81xx resets the drive; all parameters are overwritten with the standard values
Pre-Operational Initialisation 81xx
Operational Initialisation 82xx resets the drive; only parameter relevant to communication are reset
Pre-Operational Initialisation 82xx
The following applies to the assignment of the bytes marked by xx” in the column:
xx = 00
hex
With this assignment, the telegram applies to all connected devices. A change of state can
be made for all devices at the same time.
xx = device address
If a device address is given, then the change of state is only carried out for the device with
the corresponding address.
Tip!
Communication of the process data is only possible when the state is changed to Operational !