EasyManua.ls Logo

Lenze 9300 Servo PLC - Page 18

Lenze 9300 Servo PLC
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9300 Servo PLC
System blocks
2.2 Automation interface (AIF1_IO_AutomationInterface)
2-6
9300ServoPLC EN 1.4
VariableName NoteDIS formatDISAddressSignalTypeDataType
AIF1_bInB16_b Bool binary %IX41.3.0 C0855/2 hex
AIF1_bInB17_b Bool binary %IX41.3.1 C0855/2 hex
AIF1_bInB18_b Bool binary %IX41.3.2 C0855/2 hex
AIF1_bInB19_b Bool binary %IX41.3.3 C0855/2 hex
AIF1_bInB20_b Bool binary %IX41.3.4 C0855/2 hex
AIF1_bInB21_b Bool binary %IX41.3.5 C0855/2 hex
AIF1_bInB22_b Bool binary %IX41.3.6 C0855/2 hex
AIF1_bInB23_b Bool binary %IX41.3.7 C0855/2 hex
AIF1_bInB24_b Bool binary %IX41.3.8 C0855/2 hex
AIF1_bInB25_b Bool binary %IX41.3.9 C0855/2 hex
AIF1_bInB26_b Bool binary %IX41.3.10 C0855/2 hex
AIF1_bInB27_b Bool binary %IX41.3.11 C0855/2 hex
AIF1_bInB28_b Bool binary %IX41.3.12 C0855/2 hex
AIF1_bInB29_b Bool binary %IX41.3.13 C0855/2 hex
AIF1_bInB30_b Bool binary %IX41.3.14 C0855/2 hex
AIF1_bInB31_b Bool binary %IX41.3.15 C0855/2 hex
AIF1_dnInD1_p Double integer position %ID41.1 C0857 dec [inc] 65536 = 1 revolution
Function
Theinputsignalsofthe8byteuserdataoftheAIF-objectareconvertedintocorrespondingsignal
types.
Byte 1 and 2
Byte 1,2 can be used simultaneously as
binary information (up to 16 bits),
as word (e.g. as control word)
Bytes 3 and 4
Bytes 3-4 form the signal for
AIF1_nInW1_a
.
Bytes 5-6 and bytes 7-8
The meaning of these user data can be selected among different signal types. Depending on the
requirement, thesedata can be evaluated as up to 2 integer signals, 32 boolean/digital signals or one
double-integer signal.
Address range from byte 1 - 7
Byte Address
1, 2 %IB41.0 and %IB41.1
3, 4 %IB41.2 and %IB41.3
5, 6 %IB41.4 and %IB41.5
7, 8 %IB41.6 and %IB41.7
Show/Hide Bookmarks

Table of Contents

Related product manuals