9300 Servo PLC
System blocks
2.4 Automation interface (AIF3_IO_AutomationInterface)
2-18
9300ServoPLC EN 1.4
VariableName DataType SignalType Address DIS DIS format Note
AIF3_nOutW1_a Integer analog %QW43.0 +100 % = +16384
AIF3_nOutW2_a Integer analog %QW43.1 +100 % = +16384
AIF3_nOutW3_a Integer analog %QW43.2 +100 % = +16384
AIF3_nOutW4_a Integer analog %QW43.3 +100 % = +16384
AIF3_bFDO0_b Bool binary %QX43.0.0
AIF3_bFDO1_b Bool binary %QX43.0.1
AIF3_bFDO2_b Bool binary %QX43.0.2
AIF3_bFDO3_b Bool binary %QX43.0.3
AIF3_bFDO4_b Bool binary %QX43.0.4
AIF3_bFDO5_b Bool binary %QX43.0.5
AIF3_bFDO6_b Bool binary %QX43.0.6
AIF3_bFDO7_b Bool binary %QX43.0.7
AIF3_bFDO8_b Bool binary %QX43.0.8
AIF3_bFDO9_b Bool binary %QX43.0.9
AIF3_bFDO10_b Bool binary %QX43.0.10
AIF3_bFDO11_b Bool binary %QX43.0.11
AIF3_bFDO12_b Bool binary %QX43.0.12
AIF3_bFDO13_b Bool binary %QX43.0.13
AIF3_bFDO14_b Bool binary %QX43.0.14
AIF3_bFDO15_b Bool binary %QX43.0.15
AIF3_bFDO16_b Bool binary %QX43.1.0
AIF3_bFDO17_b Bool binary %QX43.1.1
AIF3_bFDO18_b Bool binary %QX43.1.2
AIF3_bFDO19_b Bool binary %QX43.1.3
AIF3_bFDO20_b Bool binary %QX43.1.4
AIF3_bFDO21_b Bool binary %QX43.1.5
AIF3_bFDO22_b Bool binary %QX43.1.6
AIF3_bFDO23_b Bool binary %QX43.1.7
AIF3_bFDO24_b Bool binary %QX43.1.8
AIF3_bFDO25_b Bool binary %QX43.1.9
AIF3_bFDO26_b Bool binary %QX43.1.10
AIF3_bFDO27_b Bool binary %QX43.1.11
AIF3_bFDO28_b Bool binary %QX43.1.12
AIF3_bFDO29_b Bool binary %QX43.1.13
AIF3_bFDO30_b Bool binary %QX43.1.14
AIF3_bFDO31_b Bool binary %QX43.1.15
AIF3_dnOutD1_p Double integer position %QD43.0 1 revolution = 65536