9300 Servo PLC
System blocks
2.5 AIF_IO_Management
2-20
9300ServoPLC EN 1.4
2.5 AIF_IO_Management
Automation interface management (module number 161)
This SB is used for the control and monitoring of special AIF-modules (fieldbus modules).
Tip!
Pleaseobserve thecorresponding OperatingInstructions for thefieldbusmodule that is plugged in.
AIF_IO_Management
AIF_bFieldBusStateBit1_b
AIF
Communication Error
AIF
Field Bus State
AIF_bCe1CommErr_b
AIF_bFieldBusStateBit2_b
AIF_bFieldBusStateBit3_b
AIF_bFieldBusStateBit5_b
AIF_bFieldBusStateBit0_b
AIF_bFieldBusStateBit6_b
AIF_bFieldBusStateBit7_b
AIF_bFieldBusStateBit4_b
Abb. 2-10 AIF_IO_Management
VariableName
DataType SignalType Address DIS DIS format Note
AIF_bCe0CommErr_b Bool binary %IX161.0.0 hex Communication error
AIF_bFieldBusStateBit0_b Bool binary %IX161.1.0 hex Field bus state bit 0
AIF_bFieldBusStateBit1_b Bool binary %IX161.1.1 hex Field bus state bit 1
AIF_bFieldBusStateBit2_b Bool binary %IX161.1.2 hex Field bus state bit 2
AIF_bFieldBusStateBit3_b Bool binary %IX161.1.3 hex Field bus state bit 3
AIF_bFieldBusStateBit4_b Bool binary %IX161.1.4 hex Field bus state bit 4
AIF_bFieldBusStateBit5_b Bool binary %IX161.1.5 hex Field bus state bit 5
AIF_bFieldBusStateBit6_b Bool binary %IX161.1.6 hex Field bus state bit 6
AIF_bFieldBusStateBit7_b Bool binary %IX161.1.7 hex Field bus state bit 7
Function
Monitoring for communication errors through a field bus module connected to the automation
interface. (Communication error CE0; LECOM-Nr.: 61; Reaction: TRIP)