4-48
Application Manual CDA3000
4 Application data sets
Active functions in field bus operation
More details of the software functions and setting options are presented
in section 5 Software functions and section 6 Control modes.
Function Effect VFC SFC FOR
IxR load
compensation
In case of load surges a higher torque is
available, and the motor heats up less
Current injection Increase in starting torque
Current-controlled
startup with ramp
stop
Protection against current overload shut-off
in acceleration from high load torques

DC holding
Rotation of the motor shaft without load is
counteracted
Magnetizing Increase in coasting and standstill torque

Table4.23 Activefunctions