5-90
Application Manual CDA3000
5  Software functions
5.4 Bus operation 
and option 
modules
This Manual details only the software parameters of the CDA3000 inver-
ter module. For more details on the field bus systems refer to the relevant
documents relating to the option modules.
5.4.1 _55 LB-LUSTBUS
Parameters for LUSTBUS 
Function Effect
• Creation of the device
addresses and baud rate for
the service and diagnostic
interface
• Adaptation of the serial inter-
face (RS232) to as PC with
the D
RIVEMANAGER software
or the K
EYPAD KP200
Parameter Function Value range FS Unit Online
81-SBAUD LUSTBUS transfer rate
9600
1200
2400
4800
19200
2880
57600
57600 Bit/s
82-SADDR LUSTBUS device address 0 ... 30 1
83-SDMMY LUSTBUS dummy parameter 0 ... 255 0
84-SWDGT LUSTBUS watchdog time setting 0.00 ... 20.00 0.00 s
85-SERR LUSTBUS error status word 00H ... FFH 00 Hex
550-SSTAT Status word of serial interface 0 ... 65535 0
551-SCNTL Control word of serial interface 0000H ... FFFFH 0000Hex
Table 5.52 Parameters from subject area _55LB LUSTBUS
Explanatory notes
• If only one inverter module is operated on the DRIVEMANAGER no
device address need be set. For more than one device, different
address parameters must be set.
• The L
USTBUS watchdog time setting is deactivated to 0.0 s at the
factory.