Application Manual CDA3000
4-37
4  Application data sets
1
2
3
4
5
6
A
DE
EN
FR
4.4.5 Comparison of 
parameters, 
rotational 
drives
Comparison of the application data sets for rotational drives with the
factory setting (152-ASTER = DRV_1):
I/O  Parameter Function
152-ASTER =
DRV_1
(FS)
ROT_1 ROT_2 ROT_3 ROT_4
Initial commissioning
151-ASTPR Original device preset DRV_1 ROT_1 ROT_2 ROT_3 ROT_4
152-ASTER Preset within the active application data set DRV_1 ROT_1 ROT_2 ROT_3 ROT_4
166-UDSSL
Control location for switchover of the active user 
data set
PARAM 1)
300-CFCON
Current open-loop/closed-loop control mode of 
the device
VFC FOR
Driving profile generator
597-RF0 Response at reference value 0 Hz OFF 0 Hz
CDA3000 inverter module inputs and outputs
ISA00 180-FISA0 Function selector analog standard input ISA00 OFF PM10 V PM10 V PM10 V PM10 V
ISA01 181-FISA1 Function selector analog standard input ISA01 OFF 0-10V 0-10 V 0-10 V
ISD00 210-FIS00 Function selector digital standard input ISD00 STR
ISD01 211-FIS01 Function selector digital standard input ISD01 STL
ISD02 212-FIS02 Function selector digital standard input ISD02 SADD1 MP-UP ENC ENC
ISD03 213-FIS03 Function selector digital standard input ISD03 OFF MP-DN ENC ENC FFTB0
OSA00 200-FOSA0 Function selector for analog output OSA00 AACTF
OSD00 240-FOS00 Function selector digital standard output OSD00 BRK_1 REF REF REF REF
OSD01 241-FOS01 Function selector digital standard output OSD01 REF ROT_0 ROT_0 ROT_0 ROT_0
OSD02 242-FOS02 Function selector digital standard output OSD02 S_RDY
User module UM-8I4O inputs and outputs
IED00 214-FIE00 Function selector digital input IED00 OFF SADD1
IED01 215-FIE01 Function selector digital input IED01 OFF FFTB0
IED02 216-FIE02 Function selector digital input IED02 OFF FFTB1
IED03 217-FIE03 Function selector digital input IED03 OFF FFTB2
IED04 218-FIE04 Function selector digital input IED04 OFF UM0
IED05 219-FIE05 Function selector digital input IED05 OFF UM1
OED01 243-FOE00 Function selector digital output OED01 OFF WIIT
1) After setting the parameters of the user data sets, change parameter value 166-UDSSL from PARAM (KEYPAD KP200,
D
RIVEMANAGER) to TERM (terminal operation).
Table 4.18 Automatic changes by means of the assistance parameter