5-38
Application Manual CDA3000
5  Software functions
5.2.5 _25 CK-Clock 
input/ Clock 
output
Figure 5.12 Scaling of clock input ISD01
Parameters for clock input/clock output
Function Effect
• Definition of the internal
processing of the clock input
• Scaling of the output fre-
quency of the clock output
• The reference value can be
set by way of a clock fre-
quency
• The actual value is mapped
onto a clock signal at
OSD01
f[Hz]
1600
-1600
0 kHz
F[kHz]
FFMNx
FFMXx
10 kHz
Parameter Function Value range FS  Unit Online
250-OCLK Multiplier for clock output OSD01 1x, 2x, 4x ... 128x 1x
251-FFMX1 CDS1: Maximum value of clock input ISD01 at 10 kHz -1600 ... 1600 50 Hz
252-FFMN1 CDS1: Minimum value of clock input ISD01 at 0 kHz -1600 ... 1600 0 Hz
253-FFMX2 CDS2: Maximum value of clock input ISD01 at 10 kHz -1600 ... 1600 50 Hz
254-FFMN2 CDS2: Minimum value of clock input ISD01 at 0 kHz -1600 ... 1600 0 Hz
255-INCLF Filter time constant for the clock input 0.002-20 0.01 s
Table 5.22 Parameters of subject area “_25 CK-Clock input/ Clock