Application Manual CDA3000
4-7
4 Application data sets
1
2
3
4
5
6
A
DE
EN
FR
4.3 Traction and lif-
ting drive
Loading one of the application data sets DRV_1 to DRV_5 into the RAM
by setting parameter 152-ASTER, in subject area “_15 FC-Initial commis-
sioning”, causes the inverter module automatically to adopt the preset
software functions as well as the presets for all the inputs and outputs for
the traction and lifting drive application.
Active functions in the preset
Function
152-ASTER =
DRV_1
DRV_2
DRV_3
DRV_4
DRV_5
Quick jog driving profile
Quick jog/slow jog
driving profile
Table sets with fixed
frequencies and ramps
Characteristic data
switchover for load
adjustment
User data set
switchover
Table 4.5 Traction and lifting drive presets
v
t
v
t
v
t
v
t
v
t
001 MODE
999 xyz
1
001 MODE
999 xyz
2